Chapter 19 Using Special Sync Output
•
If the probe is within the active portion of the frame, an alternate vertical position
Y:nnnn is also displayed, indicating the number of lines between the start of active
(Y:0) and the leading edge of the probe in the vertical direction.
Controlling the probe using the command line interface
Using the command line interface to control the probe provides more control, enables you
to change the polarity and width, and to change the format and image while maintaining
the probe pulse parameters.
To configure the probe feature:
1. Establish a session with the generator using either HyperTerminal over a serial
connection or Telnet over an Ethernet LAN. See “
Establishing a terminal session with
” on page 31 or “
Establishing a Telnet session with the generator
2. Enable the probe feature by entering the following commands:
0
// disable the frame sync on special sync output
1
// enable the probe pulse
1
// set the probe pulse polarity (0 for low or 1 for high)
10 // set pulse width to 10 pixels (range: 1 pixel to
100 // set pulse horizontal position at 100 pixels from leading
// edge of horiztonal sync pulse, in range from 0 <=
//
<
50
// set the pulse vertical position at 50 lines from leading
// edge of vertical blanking, in range from 0 <=
// PSVD < (VTOT-1)
// apply the settings
To set the lines on which the probe pulse occurs:
1. Enter the appropriate command:
Set the probe pulse to occur
Command
Once per frame
0
Once every active line
1
Once every line
3