881/882 Video Test Generator User Guide
(Rev A.22)
575
5. Enable lipsync testing in generator as follows:
a. Press the
Content key. The following information appears on the generator’s
display.
b. Choose either the
LipSyncB or LipSync image.
c. Press the
Settings key. The following information appears on the generator’s
display.
d. Set the
LSGM setting to 1 by pressing the soft keys adjacent to the bottom row until
the cursor appears on the digit. Press the + or - keys to adjust the setting up or
down.
e. Press the
Enter (Options) key to save the new setting.
Alternatively, to enable the generator to measure lipsync correction through the
command line interface, enter the following command:
LSGX:LSGM 1
// Enables lipsync testing
LSGX:LSGU
// Activates lipsync testing
6. Press the
Content key. The following information appears on the generator’s display.
7. Choose the image to use for lipsync testing.
Acer1
Acer2
Acer3
Acer4
Acer5
Acer6
Acer7
Acer8
Image ->
LipSync ->
LSGM TLAT PLAT
1
0.0000 0
->
Acer1
Acer2
Acer3
Acer4
Acer5
Acer6
Acer7
Acer8