232

Chapter 8 Working with Test Sequences

Before:

...

/tffs0/Library/TestAnalog/DMT0659.xml
SMPTEBar.img
+3.0000000E+00


...

After (modified text in bold):

...

/tffs0/Library/TestAnalog/

DMT0856.xml

PulseBar.img

+

4.0000000E+00


...

4. Save the text file as an XML file.

5. Using the Generator FTP Browser, download the format XML file from your PC to the

generator. See

Copying files from a PC to a generator

” on page 24 for instructions.