Quantum Data 881 User Manual
Page 260

242
Chapter 9 Analyzing Digital Sources and Cables
6. Put the 882EA into passthru mode.
a. Press the
Interface key to access the list of interfaces. The list of signal interfaces
appears on the generator’s display as shown below.
b. Press the
Option key to access the Passthru mode selection.
c. Enable Passthru by pressing the adjacent soft key.
d. Alternatively, to enable passthru mode via the command line interface, enter the
following command:
PDAX:PASS 1
// Enables passthru mode
To query the current state of the passthru mode via the command line, enter the
following command:
PDAX:PASS?
// Returns 0 or 1 to indicate the status
To disable passthru mode via the command line, enter the following command:
PDAX:PASS 0
// Disables passthru mode
VGA
HDMI-D
CVBS
S-VIDEO
SDI
*HDMI-H
Output
Mark#1
-
+
Passthru
-
Output
Mark#1
-
+
Passthru
+