Appendix B Image Reference
Test
Brightness control adjustment
Purpose
The wrong brightness setting may cause other tests such as Contrast, Focus, and Beam
Size to be invalid. An accurate brightness setting helps give repeatable measurements
throughout other tests.
Method
Center your light meter probe within the center square and adjust the monitor’s brightness
control to obtain the required light meter reading.
BriteBox
Description
The primary version has a single white box in the center of active video. The box size is
controlled by the MSIZ system parameter. The secondary version adds four boxes in the
corners of active video.
Test
Brightness control adjustment
Purpose
The wrong brightness setting may cause other tests such as Contrast, Focus, and Beam
Size to be invalid. An accurate brightness setting helps give repeatable measurements
throughout other tests.
Method
Center your light meter probe within the center square and adjust the monitor’s brightness
control to obtain the required light meter reading.
Test
Brightness uniformity