4000-4999 test sequence errors – Quantum Data 881 User Manual
Page 1236

APJ
Appendix C Error Messages
3011
R, G or B 6-Bit video DAC setting out of range
A combination of system calibration factors, user calibration multiplier settings and video
output level settings have resulted in one or more calculated input values to go below zero
or above the analog video Digital-to-Analog Converter’s maximum limit of 63.
3015
R, G or B 10-Bit video DAC setting out of range
A combination of system calibration factors, user calibration multiplier settings and video
output level settings have resulted in one or more calculated input values to go below zero
or above the analog video Digital-to-Analog Converter’s maximum limit of 1023.
3020
Kill EPROM image
Built in test images can not be removed from the firmware.
3025
Image not found
A test image of a given name could not be found as either a built-in test image in the
firmware or as a user defined custom image.
3050
Grayscale video DAC setting out of range
One or more internal calculations have resulted in an analog video DAC input grayscale
setting below zero or greater than 100% video level.
4000-4999 Test sequence errors
4000
Invalid format name
The test sequence contains one or more steps that have an invalid format name
parameter.
4001
Invalid image name
The test sequence contains one or more steps that have an invalid image name
parameter.
4002
No sequence memory
There is not enough unused edit buffer memory space available to start a new test
sequence editing session.
4003
Sequence memory full
There is not enough free battery backed user storage memory to save the sequence that
is in the edit buffer.
4004
Sequence not found
A test sequence of the given name could not be found in the user storage memory area.