Quantum Data 881 User Manual
Page 278

260
Chapter 9 Analyzing Digital Sources and Cables
To analyze an external HDMI/DVI signal for pixel errors:
1. Connect the HDMI/DVI transmit device to an HDMI IN connector on the generator.
2. Press the
Interface key repeatedly until the following menu appears:
3. Choose the HDMI IN connector to which the transmit device is connected by pressing
the adjacent soft key.
4. (HDMI only) If desired, monitor the video signal received on the HDMI IN connector
(see “
Monitoring HDMI 1.3 analyzer signal input
5. Press the
Tools key. The Tools menu appears on the generator’s display as shown
below.
6. Choose the
Analyzer item by pressing the adjacent soft key. The Analyzer menu
appears on the generator’s display as shown below.
7. Choose the
PIX-ERR item by pressing the adjacent soft key. The Pixel Error menu
appears as shown below.
8. (Optional) To generate a report during the test use the following procedures.
a. Press the
Options key. The following appears on the display.
b. Enable reports by pressing the soft key adjacent to
Generate Report item so that
there is a “+” sign next to it.
HDMI IN 1
HDMI IN 2
*
System
Sequence
Probe
AFC
Analyzer
Reports
ImgShift
Timing
CableTest
PIX-ERR
PRN-ERR
*
ReadRGB
Start
Settings
Exit !
!
+Generate Report
->Auto Capture