Show system, Syntax, Default configuration – Dell POWEREDGE M1000E User Manual
Page 1581: Command mode, Unit

System Management Commands
1577
Switch Status..................... OK
Switch Description................ PowerConnect 7048
Expected Code Type................ 0x100b000
Detected Code Version............. 5.31.1.46
Detected Code in Flash............ 5.31.1.46
CPLD Version...................... 5
SFS Last Attempt Status........... None
Serial Number..................... none
Up Time........................... 0 days 2 hrs 14 mins 54 secs
console#
Example – SDM Templates
This example shows the SDM Mismatch value in the Switch Status field.
console#show switch
Management
Standby Preconfig
Plugged-in
Switch
Code
SW
Switch
Status
Model ID
Model ID
Status
Version
-- ---------- ------ ------------- ------------- -----------
1
Mgmt Sw
ANFirebolt-48
ANFirebolt-48
OK
2.24.17.48
2
ANFirebolt-48
ANFirebolt-48
SDM Mismatch
2.24.17.48
show system
Use the show system command in User EXEC mode command to display
system information.
Syntax
show system [
unit
]
•
unit
— The unit number.
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
2CSPC4.XModular-SWUM200.book Page 1577 Thursday, March 10, 2011 11:18 AM