Festo Контроллер позиционирования CPX-CMAX User Manual
Page 85
3. Drive functions
3−23
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Regarding Fig. 3/6:
1 to 3: Setpoint value and actual value curves. The setpoint
value here refers to the reference setpoint value which is genĆ
erated by the trajectory planning.
4 to 6: Enlarged illustration of the control fault and the two
tolerances. The following error tolerance (11 mm) is much
greater than the positioning tolerance (0.1 to 10 mm or 0.004
to 0.394 in).
7: The MC signal determines which tolerance is used.
Overview of parameters involved (see section 5.4.6)
Parameters involved
Description
PNU
Position control
Target setpoint value: Target position
300:02
Output of the reference setpoint value generator − position
ć
1)
Actual value: Actual position
300:01
Current deviation: Position deviation
300:03
Following error tolerance (fixed: 11 mm or 0.43 in)
ć
Positioning tolerance
411:xx or
545
Force control
Target setpoint value: Target force
301:02
Output of the reference setpoint value generator − force
ć
1)
Actual value: Actual force
301:01
Force deviation
301:03
Following error tolerance (fixed: 5 N or 1.12 lbf )
ć
Force tolerance
411:xx
or 552
1)
No parameter defined, but available in trace
Tab. 3/8: Involved following error or tolerance monitoring parameters