A.2.4 c03: movement test, A.2.5 homing and identification, A.2.4 – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 325: C03: movement test, A−17, A.2.5, Homing and identification
A. Notes on commissioning and service
A−17
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
A.2.4
C03: Movement test
After parametrising, a movement test should be executed to
check the drive’s control direction. During this, the system
checks that the tubes are correctly connected. After parameĆ
trising, the CMAX expects the movement test to be executed
and indicates this by issuing C03 on the display.
The movement test must either be executed or skipped (not
recommended).
Information on executing the movement test can be found in
section 3.2.1.
A.2.5
Homing and identification
After the successful movement test, the following functions
need to be executed:
ć
Homing, see section 3.2.2
(only with measuring type "encoder").
ć
Identification, see section 3.2.5