5. Parameter

5−74

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Measuring system length (sensor length)

PNU

PNU: 1111

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Length (index = 2)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0.01 mm

0

5.000

1.000.000 0,1

°

0

500

100.000

Imperial 0.01 mm

0

5.000

1.000.000 0,1

°

0

500

100.000

With the DGCI and the DNCI the cylinder length and the measuring system length need to tally.
The sensor length is stored in the sensor interface with the DGCI.

o

The parameter value cannot be changed.

ý

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.

Measuring system serial number (sensor serial number)

PNU

PNU: 1112

Index: 1

Max index: 1

Class: Var

Data type: bitarray

Values

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Write:

Each sensor interface has a unique serial number.
The serial number can be used to identify exchanged hardware, see appendix A.3.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.