beautypg.com

Drive functions 3−15 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 77

background image

3. Drive functions

3−15

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Enable drive
CCON.ENABLE

Output Pin 2

1

0

Start
CPOS.START

Stop
CCON.STOP

1

0

1

0

1

0

1

0

1

0

24 V

0 V

Release brake
CCON.BRAKE

Operation enabled
CCON.OPEN

Drive enabled
SCON.ENABLED

Brake status

50 ms

open

closed

Fig. 3/3:

Open brake" sequence

An overview of different cases for setting and releasing the
brake is shown in Tab. 3/3.

An overview of different cases for for activating and deactivatĆ
ing the controller is shown in Tab. 3/4.