C.1.4 addressing, C.1.4, Addressing – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 408: C−10
C. Configuration with CPX node
C−10
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
C.1.4
Addressing
Example: Addresses used as from input/output word 7
8DI
2AI
4DO
8 A
8 A
MPA
1
2
3
4
5
6
Module no.: 0
I/O−Diag.Interf.
E7.0...E8.7
A7.0...A8.7
E9.0...E9.7
A9.0...A9.3
E10.0...E17.7
A10.0...A17.7
E18.0...E21.7
A18.0...A18.7
A19.0...A19.7
Fig. C/5:
CPX−FB13 address assignment example
No.
Module
DP identifier
Si
Addresses
Siemens
Input adĆ
dress
Output adĆ
dress
0
CPX−FB13 (FB13: DPV1, I/O−Diag.Interface)
192
7 ... 8
7 ... 8
1
8−way digital input module (E: CPX−8DE)
8DE
9
ć
2
4−way digital output module (A: CPX−4DA 2x)
8DA
ć
9
3
Axis controller CMAX (CPX−CMAX−C1−1),
For assignments, see Tab. C/3
192
10 ... 17
10 ... 17
4
Analogue input module (A: CPX4AE−I)
2AE
18 ... 21
ć
ć
MPA pneumatic interface (passive module)
ć
ć
ć
5
MPA1 pneumatic module
(VI VMPA1 FB EMS 8)
8DA
ć
18
6
(VI: VMPA1−FB−EMS−8)
8DA
ć
19
Tab. C/2: Input and output addresses for the example, see Fig. C/5