4. Faults and diagnostics

4−26

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Fault group 6 ć error in valve

CPX error group 106 (CPX−MMI: [Error in valve] )

No.

Message

Cause/description

Error handling

Type

1)

60

Faulty communication
with the valve or no
valve present

When switching on, only
the position measuring
system/sensor interface
was found. The valve
was not detected.

·

Check cables to the
valve.

·

Replace the valve.

Level: F2
Reset: N
Info: x

Communication between
CMAX and valve was inĆ
terrupted

·

Check the cables of
the axis string, the
valve and the sensor
step by step and exĆ
change, if necessary.

61

Valve hardware faulty

The valve reports a
hardware error.

·

Replace the valve.

Level: F2
Reset: N
Info x

Fault in initialization of
the valve.

·

Exchange valve, check
firmware update of
the CMAX.

Info: x

62

Valve over−temperature

The valve reports over−
temperature. (Ambient
temperature too high).

·

Provide sufficient
cooling.

Level: F2
Reset: F
Info: x

63

Valve is jammed

The valve piston does
not move as expected.

·

Replace the valve.

·

Also check the air
quality (5 Ģ−filter and
dry air).

Level: F2
Reset: F
Info: x

64

Load voltage of the valve
outside of the tolerance
range (undervoltage)

The valve reports inĆ
sufficient load voltage.
Either the cable beĆ
tween the CMAX and the
valve is faulty or the
valve.

·

Check the cables at
the axis string.

·

Check the valve, exĆ
change if necessary.

Level: F2
Reset: F
Info: x

1)

Level: fault level, see section 4.2.3; (can alternatively be parametrised as a warning or error)
Reset: behaviour upon reset, see section 4.2.4
Info:

ć = no info; x = additional info, see FCT or section 4.3.3