Festo Контроллер позиционирования CPX-CMAX User Manual
Page 284
5. Parameter
5−96
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Commissioning operation
configuration status
PNU
PNU: 1192
Index: 2
Max index: 8
Class: Struct
Data type: int32
Values
Without unit
Default: 0
Minimum: 0
Maximum: 4
When commissioning a certain number of parameters must be transmitted in a certain order. This
parameter provides information about the status of parametrising and about the next commissioning
step to be performed.
Possible return values
Display
= 0: Waiting for system of measurement
C00
= 1: Waiting for cylinder type
C00
= 2: Waiting for axis data
C00
= 3: Waiting for movement test
C00
= 4: Axis configuration completed
depending on respective operating mode
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.