6. Parametrisation

6−13

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

6.3

CPX module parameter and acyclic parametrising

6.3.1

CPX function numbers

Per module 64 byte module parameters (function no.
4828 + m*64 + 0...63) can be used in the system table.

CPX module parameter of the CMAX

Function no.

Contents

Description

4828 + m * 64 + 0

Module parameter 0

Standard module parameters, are not used by the
CMAX (reserved)

4828 + m * 64 + ...

Module parameters ...

CMAX (reserved).

4828 + m * 64 + 5

Module parameter 5

4828 + m * 64 + 6

Module configuration 1

Special module settings of the CMAX (reserved).

4828 + m * 64 + 7

Module configuration 2

4828 + m * 64 + 8

Parameter control byte

Function head (request control)

4828 + m * 64 + 9

Parameter status byte

4828 + m * 64 + 10

Parameter function byte

4828 + m * 64 + 11

Parameter length byte

4828 + m * 64 + 12

Data byte 1

50 byte data.
The contents depend on the request

4828 + m * 64 + ...

Data byte ...

The contents depend on the request.

4828 + m * 64 + 61

Data byte 50

4828 + m * 64 + 62

Byte 62

Not used (reserved).

4828 + m * 64 + 63

Byte 63

Tab. 6/7: CPX module parameter of the CMAX