beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 251

background image

5. Parameter

5−63

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Direct mode position deceleration

PNU

PNU: 542

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Acceleration (index = 7)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0,001 m/s

2

2.000

10

100.000

1

°/s

2

1.000

10

100.000

Imperial 0.01 ft/s

2

650

3

32.808

1

°/s

2

1.000

10

100.000

Deceleration in position control direct mode.
Depending on PNU 521:02, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Direct mode position workpiece mass

PNU

PNU: 544

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Mass (index = 5)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0.1 kg

0

0

20.000

1 kg cm

2

0

0

2.000

Imperial 1 lb

0

0

4.409

0.1 lb in

2

0

0

6.834

Workpiece mass in position control direct mode.
Depending on PNU 521:02, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.