A.2.2, Step−for−step instructions for basic parametrising, A−12 – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 320
A. Notes on commissioning and service
A−12
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
A.2.2
Step−for−step instructions for basic parametrising
Step 1:
Switch on conĆ
troller. Status C00
is now active.
1. Check status (read PNU 1192:02 −> setpoint = 0).
2. Recommendation: Write device names (PNU 121).
Basically the default value CMAX1" can be used, but an
individual name is recommendable in case you also inĆ
tend to access the controller with FCT.
3. Check version number of the firmware (read PNU 101).
Prior to parametrising you should ensure that the CMAX
is really compatible with the following project data.
Step 2:
Select commisĆ
sioning mode
4. Activate Commissioning" mode in the CCON, wait for
acknowledgement in the SCON.
STOP and ENABLE must not be set.
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
RESET
BRAKE
STOP
ENABLE
SetĆ
point
1
0
x
0
x
x
0
0
SCON
OPM2
OPM1
FCT_MMI 24VL
FAULT
WARN
OPEN
ENABLED
SetĆ
point
1
0
x
x
0
0
0
0
If the parameters are to transmitted via the cyclical I/O data
of the PLC, Parametrising" mode must be selected.
OPM2
OPM1
Operating
mode
Transmit parameters via
1
0
Commissioning CI/DIAG or module paraĆ
meters, e.g. DPV1
1
1
ParametrisaĆ
tion
Usage of cyclical I/O data
bytes 2..8