A. Notes on commissioning and service

A−12

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

A.2.2

Step−for−step instructions for basic parametrising

Step 1:

Switch on conĆ
troller. Status C00
is now active.

1. Check status (read PNU 1192:02 −> setpoint = 0).

2. Recommendation: Write device names (PNU 121).

Basically the default value CMAX1" can be used, but an
individual name is recommendable in case you also inĆ
tend to access the controller with FCT.

3. Check version number of the firmware (read PNU 101).

Prior to parametrising you should ensure that the CMAX
is really compatible with the following project data.

Step 2:

Select commisĆ
sioning mode

4. Activate Commissioning" mode in the CCON, wait for

acknowledgement in the SCON.
STOP and ENABLE must not be set.

B7

B6

B5

B4

B3

B2

B1

B0

CCON

OPM2

OPM1

LOCK

RESET

BRAKE

STOP

ENABLE

SetĆ
point

1

0

x

0

x

x

0

0

SCON

OPM2

OPM1

FCT_MMI 24VL

FAULT

WARN

OPEN

ENABLED

SetĆ
point

1

0

x

x

0

0

0

0

If the parameters are to transmitted via the cyclical I/O data
of the PLC, Parametrising" mode must be selected.

OPM2

OPM1

Operating
mode

Transmit parameters via

1

0

Commissioning CI/DIAG or module paraĆ

meters, e.g. DPV1

1

1

ParametrisaĆ
tion

Usage of cyclical I/O data
bytes 2..8