C. Configuration with CPX node

C−33

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Example of I/O assignment record select mode

Module output data

Module input data

AW

Contents

Address

EW

Contents

Address

AW129

CCON:
Bit

Name

0

ENABLE

1

STOP

2

BRAKE

3

RESET

4

ć (reserved)

5

LOCK

6

OPM1

= 0

7

OPM2

= 0

A129.0
A129.1
A129.2
A129.3
A129.4
A129.5
A129.6
A129.7

EW129

SCON:
Bit

Name

0

ENABLED

1

OPEN

2

WARN

3

FAULT

4

24VL

5

LOCK

6

OPM1

= 0

7

OPM2

= 0

E129.0
E129.1
E129.2
E129.3
E129.4
E129.5
E129.6
E129.7

CPOS:
Bit

Name

0

ć (reserved)

1

START

2

HOME

3

JOGP

4

JOGN

5

TEACH

6

ć (reserved)

7

ć (reserved)

A129.8
A129.9
A129.10
A129.11
A129.12
A129.13
A129.14
A129.15

SPOS:
Bit

Name

0

ć (reserved)

1

ACK

2

MC

3

TEACH

4

MOV

5

DEV

6

STILL

7

REF

E129.8
E129.9
E129.10
E129.11
E129.12
E129.13
E129.14
E129.15

AW130

Record No.

A130.0...7

EW130

Feedback record no.

E130.0...7

reserved

A130.8...15

RSB:
Bit

Name

0

RC1

1

RCC

2

COM1

3

RCE

4

VLIM

5

XLIM

6

ć (reserved)

7

ć (reserved)

E130.8
E130.9
E130.10
E130.11
E130.12
E130.13
E130.14
E130.15

AW131

reserved

A131.0...15

EW131

Primary actual value
(4 bytes int32)

E131.0...15

AW132

A132.0...15

EW132

(4 bytes, int32)

E132.0...15

Tab. C/11: Addresses of the control and status bytes in the example Fig. C/16, example of

record select mode