Festo Контроллер позиционирования CPX-CMAX User Manual
Page 175
4. Faults and diagnostics
4−39
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Information and details on the faults (PNU 202)
Info (bit 11 ... 08)
Details (bit 07... 00)
Value
Description
Value
Description
3
Cause of fault E44
(teaching not
1
Not specified.
(teaching not
possible)
2
In direct operating it is not possible to teach (no teach target).
possible)
3
Homing not carried out.
4
Commissioning: Unknown teach target specified in
parameter 1.
5
Record selection: Impermissible record number (0 or > 64)
6
Record selection: Impermissible control mode preset in the
selected record
7
Commissioning: Teaching lower software end
position >= upper software end position not permissible
8
Commissioning: Teaching upper software end
position <= lower software end position not permissible
9
Commissioning: Teaching is not permissible while a commisĆ
sioning operation is being carried out.
4
Record number
nn
In the event of a general fault in operating mode Record
select, the number of the record started last is entered.
Value range nn: 0 to 255
5
Commissioning
operation
nn
In the event of a general fault in commissioning mode,
the commissioning operation started last is entered.
Value range nn: 0 to 255