A. Notes on commissioning and service
A−19
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Parameters
Permissible deviations for nominal/actual comparison
Prior to transfer of SN
1)
After transfer of SN
2)
After identification
Cylinder
Type
no deviation
no deviation
no deviation
Nominal/effective
length
3)
5 mm
5 mm
5 mm
Diameter
no deviation
no deviation
no deviation
PR diameter
4)
no deviation
no deviation
no deviation
Measuring system
Type
no deviation
no deviation
no deviation
Nominal length
5 mm
5 mm
5 mm
Serial number
any changes
any changes
5)
any changes
5)
Valve
Type
no deviation
no deviation
no deviation
Serial number
any changes
no deviation
no deviation
1)
Prior to transfer of the serial numbers any changes to the setpoint configuration are permissible if
there is no actual configuration. A complete actual configuration is currently only available when
using the DGCI.
2)
After transfer of the SN or the identification, these tolerances not only apply to variations between
the setpoint values and actual values, but also between old and new setpoint values.
3)
Only a cylinder length to which both actual values are compared is projected.
4)
Piston rod diameter
5)
No deviation permissible with the DGCI.
Tab. A/2: Permissible deviations for nominal/actual comparison
Optimize parameters
Various parameters can still be modified after commissioning
in order to optimize the project. The cylinder length can, for
example, be modified by up to 5.00 mm in order to be able to
move right up to cylinder end position with force control.