4. Faults and diagnostics

4−22

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Fault group 4 ć system error A

CPX error group 104 (CPX−MMI: [System error A] )

continued

No.

Message

Cause/description

Error handling

Type

1)

44

Teaching not possible

2)

Teaching (falling edge on
CPOS.TEACH) is trigĆ
gered unintentionally
through disconnection or
switching off the control.

·

Only activate
CPOS.TEACH = 1 (preĆ
pare teaching) directly
before the teaching
process. Always end
teaching immediately.

Level: F1
Reset: R
Info: x

Teaching not possible
during direct operating.

·

Change operating
mode.

Teaching not possible
during active commisĆ
sioning operation.

·

First end commissionĆ
ing operation.

In BA commissioning the
teaching target in paraĆ
meter 1 is invalid.

·

Correct parameter 1.

Without reference teachĆ
ing is not possible.

·

Perform homing prior
to teaching.

Lower software end
position (SWEL) is
larger/the same as the
upper software end
position when teaching
the SWEL to BA comĆ
missioning. It is not
adopted.

·

Teach upper SWEL
first.

·

Correct the teach
position.

Continued...

Upper software end
position (SWEP) is
smaller/the same as the
lower software end
position when teaching
the SWEP to BA comĆ
missioning. It is not
adopted.

·

Teach lower SWEP
first.

·

Correct the teach
position.

1)

Level: fault level, see section 4.2.3; (can alternatively be parametrised as a warning or error)
Reset: behaviour upon reset, see section 4.2.4
Info:

ć = no info; x = additional info, see FCT or section 4.3.3

2)

For exact cause, see diagnostic memory.