4. Faults and diagnostics
4−22
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Fault group 4 ć system error A
CPX error group 104 (CPX−MMI: [System error A] )
continued
No.
Message
Cause/description
Error handling
Type
1)
44
Teaching not possible
2)
Teaching (falling edge on
CPOS.TEACH) is trigĆ
gered unintentionally
through disconnection or
switching off the control.
·
Only activate
CPOS.TEACH = 1 (preĆ
pare teaching) directly
before the teaching
process. Always end
teaching immediately.
Level: F1
Reset: R
Info: x
Teaching not possible
during direct operating.
·
Change operating
mode.
Teaching not possible
during active commisĆ
sioning operation.
·
First end commissionĆ
ing operation.
In BA commissioning the
teaching target in paraĆ
meter 1 is invalid.
·
Correct parameter 1.
Without reference teachĆ
ing is not possible.
·
Perform homing prior
to teaching.
Lower software end
position (SWEL) is
larger/the same as the
upper software end
position when teaching
the SWEL to BA comĆ
missioning. It is not
adopted.
·
Teach upper SWEL
first.
·
Correct the teach
position.
Continued...
Upper software end
position (SWEP) is
smaller/the same as the
lower software end
position when teaching
the SWEP to BA comĆ
missioning. It is not
adopted.
·
Teach lower SWEP
first.
·
Correct the teach
position.
1)
Level: fault level, see section 4.2.3; (can alternatively be parametrised as a warning or error)
Reset: behaviour upon reset, see section 4.2.4
Info:
ć = no info; x = additional info, see FCT or section 4.3.3
2)
For exact cause, see diagnostic memory.