5. Parameter

5−38

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Filter diagnostic message

PNU

PNU: 228

Index: 2

Max index: 3

Class: Struct

Data type: bitarray

Values

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Write:

0000 0000 0000 0000 0000 0000 00xx xxxx

This filter allows you to exclude certain faults and warnings from the diagnostic memory records.
This makes sense for faults that are part of the normal operating cycle because they are inherent to
the process (load voltage errors) or because they occur frequently for other reasons. For allocation,
see 4.4.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Fault behaviour configuration

PNU

PNU: 228

Index: 3

Max index: 3

Class: Struct

Data type: bitarray

Values

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Write:

0000 0000 0000 0000 0000 000x xxxx xxxx

Some of the faults can also be reported as warnings. This concerns in particular function monitoring,
such as maintaining the software end position. Often the right correct reaction depends on the apĆ
plication in these cases. For allocation, see 4.4.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.