A. Notes on commissioning and service

A−4

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Delivery status
(after switching on for the first time or after data
reset)

ć

The connected components (valve and measuring sysĆ
tem/ sensor interface) are automatically searched for at
the axis interface, the information received are read.

ć

The recognized components are

not automatically acĆ

cepted as the setpoint configuration.

ć

Without complete parametrising

1)

of the axis data, the

controller cannot be activated. Actual values are not upĆ
dated in that case.

Standard startup

ć

The connected components (valve and measuring sysĆ
tem/ sensor interface) are automatically searched for at
the axis interface, the information received are read.

ć

The factual configuration found is compared to the setĆ
point configuration. Deviations lead to errors, a controller
is not activated. This error can only be acknowledged
after a parametrisation

1)

.

Recognisable parameters

The CMAX ascertains all the parameter values stored in the
drive, sensor (measuring system) and valve automatically.
The FCT PlugIn can read these values from the controller,
they must not be entered in the FCT project. The ascertained
data cannot be overwritten.

1)

Parametrisation executed": Each parameter from the
area of axis data/mechanical system (also homing with
DNCI) receives appropriate data.