Diagnostic event 3: reset – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 177
4. Faults and diagnostics
4−41
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
4.3.4
Diagnostic code and additional information with reset, switching on
and configuration
The diagnostic memory contains other diagnostic events
along with faults and warnings. Here the contents of what the
diagnostic number and additional information means is deĆ
scribed.
Diagnostic event 3: Reset
A reset command was executed with FCT or with the PLC.
Diagnostic number
No.
Description
1
Successful: All the fault messages were deleted.
2
Not successful: Not all messages could be deleted.
3
New start of the axis performed.
Additional information
Info
Description
Byte 1
Number of resets so far
Byte 2
reserved
Byte 3 + 4 In case value > 0: Reset duration in milliseconds after restart of the axis