4. Faults and diagnostics

4−45

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Fault messages filter

The fault messages filter allows you to exclude certain faults
and warnings from the diagnostic memory records. This
makes sense for faults that are part of the normal operating
cycle because they are inherent to the process (load voltage
errors) or because they occur frequently for other reasons.

Warning: Even if these faults are not entered in the diagnostic
memory, the respective fault is reported in the corresponding
fault situation and has to be acknowledged.

PNU 228:02 ć fault messages filter

Do you want this fault / warning to be entered in the diagnostic memory?

Bit

Description

SpecifiĆ
cation

0

W08: Identification was not executed

1

1

W35: Actual position outside of the software end positions

1

2

W42: not used control bits set

1

3

E50: Supply pressure is too low

1

4

E51: Load voltage outside of tolerance range

1

5

W57: Timeout at the diagnostic interface

1

6

W68: Valve warning overtemperature

1

7 ... 31

reserved (=: 0 !)

0

Tab. 4/16: Configuration of the diagnostic messages ć fault messages filter

Configuration of fault messages

Some of the faults can also be reported as warnings. This
concerns in particular function monitoring, such as maintainĆ
ing the software end position. Often the right correct reaction
depends on the application in these cases.

With faults where both reactions are possible you can define
the behaviour of the CMAX.