2 device data, Device data, Sections 5.4.2 – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 213: Section 5.4.2
5. Parameter
5−25
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
5.4.2
Device data
Manufacturer hardware version
PNU
PNU: 100
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0x0100
Minimum: −
Maximum: −
Coding of the CMAX hardware version.
The version number is BCD−encoded, the upper 16 bits are not used.
Format: 0x0000HHNN (HH = main version, NN = secondary version)
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Manufacturer firmware version
PNU
PNU: 101
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0x0100
Minimum: −
Maximum: −
Coding of the CMAX firmware version. The version number is encoded as BCD.
Format: 0xBBBBHHNN
(BBBB = build number/output version, HH = main version, NN = secondary version)
Example: 0x05050100 corresponds to the version V01.00.0505
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Version FHPP
PNU
PNU: 102
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0x0110
Minimum: −
Maximum: −
Coding of the implemented FHPP version.
The FHPP version is changed in the event of fundamental adjustments of the FHPP definition.
Format: 0x0000HHNN (HH = main version, NN = secondary version)
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.