1 overview of diagnostics options, Overview of diagnostics options – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 139
4. Faults and diagnostics
4−3
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
4.1
Overview of diagnostics options
The CMAX supports a number of different options for diagĆ
nostics and error handling in the CPX terminal.
An overview is shown in Tab. 4/1.
Access/
Function
Diagnostics
option
Brief description
Detailed
description
Local
Display on the
device
LED display, disĆ
play / 7−
segment display
The LEDs and the display directly indiĆ
cate operating and fault statuses.
Fast on −the−spot" diagnosis.
CMAX system
description
CPX−MMI
The CPX−MMI can be used to display the
CPX module diagnosis
1)
.
Description of the
CPX−MMI
Local
with PC (e.g.
during startup)
FCT with CMAX
plug−in
Plain−text display of all diagnostic inĆ
formation during startup and servicing.
Full access to the diagnostic functionalĆ
ity of the CMAX.
Help for the CMAX
FCT PlugIn
CPX−FMT
The CPX−FMT can be used to display the
CPX module diagnosis
1)
.
Help for the CPX−FMT
PLC
via I/O data
Module output
and input data
Diagnostic information is constantly
transferred in the SCON status byte
(e.g. actual values, WARN and FAULT
bits etc.). Direct access to the status
(e.g. current position) and diagnostic
status via the CPX node.
CPX status bits,
I/O diagnostic
interface
The CPX module diagnosis
1)
is reported
to the CPX node
Optimum integration
into the CPX module concept.
PLC
via communiĆ
FHPP diagnostics
Diagnostic parameters
via communiĆ
cations profile
Diagnostic memory
1)
The CPX diagnostics only show the fault groups of the CMAX.
Tab. 4/1: Diagnostics options