5. Parameter
5−101
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Start configuration
PNU
PNU: 1195
Index: 1 ... 5
Max index: 5
Class: Struct
Data type: int32
Values
See description of the respective index.
Default: 0
Minimum: −
Maximum: −
These are important configuration data at the time of adopting the serial numbers. The current conĆ
figuration may only be modified within certain limits after this point in time.
Index
Value
Setpoint
configuration
Unit
Tolerance
1
Cylinder length
PNU 1101
Length (index 2)
5.00 mm
2
Sensor length
PNU 1111
Length (index 2)
5.00 mm
3
Sampling time
ć
1 Ģsec
−
4
Mounting position
PNU 1140
Mounting angle (index 12)
3°
5
Supply pressure
PNU 1141
Pressure (index 4)
1 bar
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Notes on PNU 1195:
The actual configuration is
ć
compatible: The actual configuration corresponds with
the setpoint configuration within the permissible limits.
Serial numbers may vary.
ć
identical: The actual configuration corresponds with the
identification configuration within the permissible limits.
The serial numbers are identical.
If the configuration is not identical, warning W08 (component
exchanged) is issued upon the first start. If it is not compatĆ
ible, error message E01 (configuration error) is issued. The
application data is used to check whether certain changes
are permissible without resetting the identification data.
Only automatically recognized configuration data can be
compared to the setpoint configuration.