Festo Контроллер позиционирования CPX-CMAX User Manual
Page 228
5. Parameter
5−40
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Pressure values
PNU
PNU: 302
Index: 1 ... 3
Max index: 3
Class: Array
Data type: int32
Values
Unit: Pressure (index = 4)
Linear drive
Semi−rotary drive
Dimension Default
Minimum
Maximum
Dimension Default
Minimum
Maximum
SI 0,1 bar
−
−120
120
0,1 bar
−
−120
120
Imperial 1 psi
−
−174
174
1 psi
−
−174
174
Index
Value
1
Pressure valve chamber 1
2
Pressure valve chamber 2
3
Calculated supply pressure
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Count of positioning commands
PNU
PNU: 305
Index: 1
Max index: 4
Class: Struct
Data type: int32
Values
Without unit
Default: 0
Minimum: 0
Maximum: 2.147.483.647
Total of start commands of the position controller that were executed.
Jogging, homing or identifications are not counted.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Count of force commands
PNU
PNU: 305
Index: 2
Max index: 4
Class: Struct
Data type: int32
Values
Without unit
Default: 0
Minimum: 0
Maximum: 2.147.483.647
Total of start commands of the force control that were executed.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.