beautypg.com

4 direct operating mode (direct mode), Direct operating mode (direct mode), Section 3.4 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 130

background image

3. Drive functions

3−68

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

3.4

Direct operating mode (direct mode)

In the Operation enabled" state (direct mode), a positioning
task is formulated directly in the I/O data, which is transĆ
mitted by the CPX node (e.g. via the fieldbus). The setpoint
values are reserved in the PLC here.

Typical applications

The function is used in the following situations:

ć

Moving to any position within the effective stroke.

ć

The target positions are unknown during designing or
change frequently (e.g. several different workpiece posiĆ
tions).

ć

A traversing profile consisting of chaining records is not
necessary.

ć

The drive is to continuously follow a setpoint value.

ć

The position setpoints should be reserved in the PLC for
another reason.

Typical causes of error in applications

ć

No referencing carried out.

ć

Target position or target force cannot be reached or are
outside of the software end positions.

ć

Timeout (target position or target force are not reached).