6 project data, Project data – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 240
5. Parameter
5−52
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
5.4.6
Project data
General description of the dimensional reference system, see
section B.2.
Project zero point
PNU
PNU: 500
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Unit: Position (index = 1)
Linear drive
Semi−rotary drive
Dimension
Default Minimum
Maximum
Dimension Default Minimum Maximum
SI 0.01 mm
0
−1.000.000 1.000.000 0,1
°
0
−100.000
100.000
Imperial 0.001 in
0
−393.701
393.701
0,1
°
0
−100.000
100.000
Reference point for position values in the application. See section B.2.
o
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
ý
After writing, controller recalculation is carried out.