5. Parameter

5−73

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Piston rod diameter

PNU

PNU: 1103

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Diameter (index = 11)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0.01 mm

0

0

20.000

0.01 mm

0

0

20.000

Imperial 0.01 mm

0

0

20.000

0.01 mm

0

0

20.000

The piston rod diameter cannot be recognized automatically. However, the Festo standard drives
have a fixed allocation of cylinder diameters to piston rod diameters. This allocation is stored in the
FCT.
With other drives and special applications, the piston rod diameter can be parametrised as required
by using the user−defined type.

o

The parameter value cannot be changed.

ý

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.

Measuring system type (sensor type)

PNU

PNU: 1110

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 0

Minimum: 1

Maximum: 4

The sensor type is read from the sensor interface.
If the sensor interface delivers no known type, a fault (E04) is generated. The sensor interface is not
commissioned in this case.
ID

Type

0

Unknown

1

Digital position measuring system DGCI

2

Digital position measuring external

3

Potentiometer

4

Encoder

255

Impermissible type, poss. firmware update?

o

The parameter value cannot be changed.

ý

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.