Festo Контроллер позиционирования CPX-CMAX User Manual
Page 261
5. Parameter
5−73
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Piston rod diameter
PNU
PNU: 1103
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Unit: Diameter (index = 11)
Linear drive
Semi−rotary drive
Dimension
Default
Minimum
Maximum
Dimension Default
Minimum
Maximum
SI 0.01 mm
0
0
20.000
0.01 mm
0
0
20.000
Imperial 0.01 mm
0
0
20.000
0.01 mm
0
0
20.000
The piston rod diameter cannot be recognized automatically. However, the Festo standard drives
have a fixed allocation of cylinder diameters to piston rod diameters. This allocation is stored in the
FCT.
With other drives and special applications, the piston rod diameter can be parametrised as required
by using the user−defined type.
o
The parameter value cannot be changed.
ý
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
ý
After writing, controller recalculation is carried out.
Measuring system type (sensor type)
PNU
PNU: 1110
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0
Minimum: 1
Maximum: 4
The sensor type is read from the sensor interface.
If the sensor interface delivers no known type, a fault (E04) is generated. The sensor interface is not
commissioned in this case.
ID
Type
0
Unknown
1
Digital position measuring system DGCI
2
Digital position measuring external
3
Potentiometer
4
Encoder
255
Impermissible type, poss. firmware update?
o
The parameter value cannot be changed.
ý
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
ý
After writing, controller recalculation is carried out.