Festo Контроллер позиционирования CPX-CMAX User Manual
Page 203
5. Parameter
5−15
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
To perform this task, the following default values are defined
first. Force control is not required, the values are not taken
into account.
Parameter
PNU
Value
Comment
Speed
600
1000 (= 1 m/s)
Do not use the maximum possible values
from the identification data
Acceleration
602
1000 (= 1 m/s
2
)
from the identification data.
Braking ramp
603
1000 (= 1 m/s
2
)
Workpiece mass
605
0
(= 0 kg)
No workpiece mass in normal status
Tolerance
606
50
(= 0.5 mm)
Tolerance = 0.5 mm
Tab. 5/11: Example of default values: Specify default values
Record list: All blank fields in the record list do not need to be
parametrised explicitly. The record control bytes 1+2 can be
used as preset.
ReĆ
cord
No.
RCB1 RCB2 RPC
(Low word)
SetĆ
point
value
Pre−
seĆ
lect
Speed Accel. Delay WP
mass
Tolerance Force
ramp
Bit 0
0001
h
Bit 2
0004
h
Bit 3
0008
h
Bit 5
0020h
Bit 6
0040h
Bit 8
0100h
1
C000 0000
h
7500
2
C000 0020
h
14550
120
3
C000 002D
h
20520
400
200
200
250
4
C000 0000
h
2000
Tab. 5/12: Example of default values: Record list