5. Parameter

5−18

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

PNU

1)

Properties

1)

Name (DE)

PNU

UL

NB

IB

SH

RW

Unit

Type

Class

Name (DE)

Max

IND

Diagnostics, see section 5.4.3).

200

X

100

Diagnostic event

Array

int32

0

R

201

X

100

Diagnostic number

Array

int32

0

R

202

X

100

Time stamp time of day

Array

int32

0

R

203

X

100

Additional information

Array

bitarray

0

R

204

1

5

Reserved

Struct int32

0

R

204

2

5

Reserved

Struct int32

0

R

204

3

5

Clear memory

Struct int32

0

RW

SH

UL

204

4

5

Number of entries

Struct int32

0

R

204

5

5

Number of unread entries

Struct int32

0

RW

UL

220

X

3

Current faults

Array

bitarray

0

R

221

X

3

Current warnings

Array

bitarray

0

R

222

X

100

Time stamp: operating day

Array

int32

0

R

224

1

1

Currently displayed fault on
display

Var

int32

0

R

225

1

1

Active fault level

Var

int32

0

R

226

1

1

Currently displ. warning on
the FCT

Var

int32

0

R

227

X

89

Error status for FCT

Array

bitarray

0

R

228

1

3

Diagnostic events filter

Struct bitarray

0

RW

SH

228

2

3

Diagnostic messages filter

Struct bitarray

0

RW

SH

228

3

3

Fault configuration configurĆ
ation

Struct bitarray

0

RW

SH

Process data, see section 5.4.4

300

X

3

Position values

Array

int32

1

R

301

X

3

Force values

Array

int32

3

R

302

X

3

Pressure values

Array

int32

4

R

305

1

4

Count of positioning comĆ
mands

Struct int32

0

R

305

2

4

Count of force commands

Struct int32

0

R

305

3

4

Cumulated stroke length

Struct int32

0

R

305

4

4

Cumulated stroke length fract. Struct int32

0

R

307

1

1

Current speed

Var

int32

6

R

308

1

1

Extended axis status

Var

bitarray

0

R

309

1

1

Valve output value

Var

int32

0

R

1)

see Tab. 5/15