5. Parameter
5−36
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Time stamp: day of operation .
PNU
PNU: 222
Index: 1 ... 100
Max index: 100
Class: Array
Data type: int32
Values
Days
Default: 0
Minimum: −
Maximum: −
Time of the current operating day in milliseconds at the time when the fault occurs.
This time stamp is not a real−time clock. The time is read from the device data PNU 140 when the
fault occurs.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Current error code on display
PNU
PNU: 224
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0
Minimum: −
Maximum: −
Fault number currently shown on the display. This makes synchronisation between the display in the
FCT and the CMAX possible. It is always the fault that occurred first that is displayed.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Current fault level
PNU
PNU: 225
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0
Minimum: −
Maximum: −
In this way the FCT can display the current status of the CMAX in accordance with section 4.2.3.
The most serious current fault is always responsible for the current fault level.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.