5. Parameter
5−88
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
5.4.15 Identification
Identification settings
PNU
PNU: 1170
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0
Minimum: 0
Maximum: 1
The parameter allows you to make certain settings that concern identification.
= 0: Identification permits high accelerations
= 1: Only perform the static identification (low accelerations)
o
The parameter value cannot be changed.
ý
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
ý
After writing, controller recalculation is carried out.
Identification status
PNU
PNU: 1171
Index: 1
Max index: 1
Class: Var
Data type: bitarray
Values
Default:
0000 0000 0000 0000 0000 0000 0000 0000
Write:
−
Current status according to the identification carried out last.
Bit 0 = 0: Identification has not yet been carried out.
= 1: Identification has been carried out at least once.
Bit 1 = 0: Results of the static identification are not available.
= 1: Static identification carried out successfully.
Bit 2 = 0: Results of the dynamic identification are not available.
= 1: Dynamic identification carried out successfully.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.