A. Notes on commissioning and service

A−31

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

A.4.2

Start record

SCON.ENABLED = 1
SCON.OPEN = 1

[m]

SCON.ACK = 1

Delay time

1 bus cycle

CPOS.START = 1

CPOS.START = 0

Record carried out

SCON.ACK = 0

[m]

[m]

[m]

[m]

[m]

Operation enabled

CPOS.START = 0

Output data byte 3

= Target record numbe

r

[o]

SCON.ACK = 1

SCON.ACK = 0

SCON.ACK = 0

SCON.ACK = 1

SCON.MC = 0

SCON.MC = 1

Preparing the starting edge

Starting edge

For all fieldbuses that do not support consistent data transmission, it is necessary to wait one bus cycle
after entering the record number during which the record number on the fieldbus is transmitted to the
CMAX.
Recommendation: with most control systems the PLC cycle is longer than the bus cycle −> delay time = 1
PLC cycle

Reset start in order to reduce the delay time next time.

It is only required to wait for MC if reaching the target position is
necessary for the further process.

[m]

[o]

This action is mandatory.

This action is a recommendation. It
does not have to be carried out

[m]

[o]