5. Parameter

5−51

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Record force ramp

PNU

PNU: 412

Index: 1

Max index: 64

Class: Array

Data type: int32

Values

Unit: Force ramp (index = 8)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

SI 1 N/s

0

10

100.000

p

rotary drives.

Imperial 1 lbf/s

0

2

22.481

The force ramp permits setting the increasing speed of the force. The controller generates a
sin

2

−shaped increase of the setpoint force for optimization of the controller behaviour, see

section B.8.7.

Default values: For position control:

ć

For force control:

RPC bit 8

Default value from parameter PNU 608

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.