12 application settings, Application settings, Section 5.4.1 – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 265
5. Parameter
5−77
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
5.4.12 Application settings
Offset axis zero point
PNU
PNU: 1130
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Unit: Position (index = 1)
Linear drive
Semi−rotary drive
Dimension
Default
Minimum
Maximum
Dimension Default
Minimum
Maximum
SI 0.01 mm
0
−1.000.000 1.000.000 0,1
°
0
−100.000
100.000
Imperial 0.001 in
0
−393.700
393.700
0,1
°
0
−100.000
100.000
Difference between the axis zero point (AZ) and the reference position (REF) or difference between
the axis zero point (AZ) and the sensor zero point (SZ).
The axis zero point (AZ) is calculated as:
AZ = REF + offset axis zero point (DNCI)
or
AZ = SZ + offset axis zero point (external measuring system: potentiometer)
The axis zero point must be placed on the cylinder zero point for servo−pneumatic drives. With the
DGCI the measuring system is calibrated, specification of an offset is not permitted.
o
The parameter value cannot be changed.
ý
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
ý
After writing, controller recalculation is carried out.
Homing method
PNU
PNU: 1131
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: −17
Minimum: −128
Maximum: 127
Defines the method by which the drive performs homing, see section 3.2.2.
hex
dec
Description
23h
35
Adopt current actual position as reference position
EFh
−17
Searching for negative stop
EEh
−18
Searching for positive stop
o
The parameter value cannot be changed.
ý
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.