beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 43

background image

2. I/O data and sequence control

2−15

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Status byte 2 (SPOS) ć record select mode

Bit

EN

Description

B0
HALT

Halt

Reserved (= 0).

B1
ACK

Acknowledge
Start

= 0: Ready to start
= 1: Start executed

1)

B2
MC

Motion
Complete

= 0: Positioning task active
= 1: Positioning task completed, possibly with error

2)

B3
TEACH

Acknowledge
Teach

= 0: Teaching carried out, actual value is transferred
= 1: Ready for teaching

B4
MOV

Axis is

moving

Movement monitoring
= 0: Drive does not move.

(Axis speed signal < limit value)

= 1: Drive is moving

B5
DEV

Following
error

Following error or tolerance monitoring
= 0: No following error / within tolerance
= 1: Following error active / outside of tolerance

B6
STILL

Stand

still

warning

Standstill monitoring.
= 0: Standstill warning is not active
= 1: Standstill warning is active, drive moved after MC (position control)

B7
REF

Axis is
referenced

= 0: Referencing must be carried out
= 1: Reference information present, homing not necessary

1)

When programming the handshake between CPOS.START and SPOS.ACK, the registered faults
must always be taken into consideration as well, since SPOS.ACK is not set in the event of a fault.

2)

MC is set for the first time after switching on (Drive disabled" status).