A.3.2 exchanging components, A.3.2, Exchanging components – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 329: A−21, Exchange of a component
A. Notes on commissioning and service
A−21
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
A.3.2
Exchanging components
Nominal/actual comparison of the hardware configuration
With each new calculation of the controller, a nominal/actual
comparison between the current hardware configuration
(actual configuration) and the setpoint configuration is perĆ
formed.
Setpoint configuration
The setpoint configuration consists of the values for the
drive configuration parametrised by the user.
Actual configuration
The actual configuration consists of values for the hardware
components ascertained during the automatic hardware
recognition.
Exchange of a component
The CMAX identifies an exchange as specified in Tab. A/4.
Component
Component exchanged for component ...
of the same type and size
of another type or size
Cylinder/drive
DGCI: Recognition based on serial
number of the measuring system
DGCI: Recognition based on length and
diameter information in the measuring
system
Other drives: recognition not possible
Other drives: recognition not possible
Valve
Recognition based on serial number
Recognition based on type information
Measuring system
DGCI: Recognition based on serial
number
DGCI: Recognition based on length and
diameter information
Other measuring systems: recognition
not possible
Other measuring systems: recognition
of the design based on sensor interĆ
face, no length information.
Sensor interface
Recognition based on serial number
Recognition based on type information
Tab. A/4: Exchange of a component − recognition by the CMAX