5. Parameter

5−75

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Valve type

PNU

PNU: 1120

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 0

Minimum: 1

Maximum: 5

The valve type is read from the valve. The type is always recognized. If the valve delivers no known
type, a fault (E04) is generated. The valve is not commissioned in this case.
ID

Valve type

0

Not configured

1

VPWP−2

2

VPWP−4

3

VPWP−6

4

VPWP−8

5

VPWP−10

o

The parameter value cannot be changed.

ý

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.

Valve serial number

PNU

PNU: 1121

Index: 1

Max index: 1

Class: Var

Data type: bitarray

Values

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Write:

Each valve has a unique serial number.
The serial number is important for identifying exchanged hardware, see appendix A.3.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.