5. Parameter
5−75
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Valve type
PNU
PNU: 1120
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 0
Minimum: 1
Maximum: 5
The valve type is read from the valve. The type is always recognized. If the valve delivers no known
type, a fault (E04) is generated. The valve is not commissioned in this case.
ID
Valve type
0
Not configured
1
VPWP−2
2
VPWP−4
3
VPWP−6
4
VPWP−8
5
VPWP−10
o
The parameter value cannot be changed.
ý
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
ý
After writing, controller recalculation is carried out.
Valve serial number
PNU
PNU: 1121
Index: 1
Max index: 1
Class: Var
Data type: bitarray
Values
Default:
0000 0000 0000 0000 0000 0000 0000 0000
Write:
−
Each valve has a unique serial number.
The serial number is important for identifying exchanged hardware, see appendix A.3.
o
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.