5. Parameter
5−19
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
PNU
1)
Properties
1)
Name (DE)
PNU
UL
NB
IB
SH
RW
Unit
Type
Class
Name (DE)
Max
IND
Record list, see section 5.4.5
400
1
3
Setpoint record number
Struct int32
0
R
400
2
3
Actual record number
Struct int32
0
R
400
3
3
Record status byte
Struct bitarray
0
R
401
X
64
Record control byte 1
Array
bitarray
0
RW
SH
UL
402
X
64
Record control byte 2
Array
bitarray
0
RW
SH
UL
403
X
64
Record param. Control
Array
bitarray
0
RW
SH
UL
404
X
64
Record setpoint value
Array
int32
1, 3
RW
SH
UL
405
X
64
Record preselection value
Array
int32
div.
RW
SH
UL
406
X
64
Record velocity
Array
int32
6
RW
SH
UL
407
X
64
Record acceleration
Array
int32
7
RW
UL
408
X
64
Record deceleration
Array
int32
7
RW
UL
410
X
64
Record workpiece mass
Array
int32
5
RW
UL
411
X
64
Record tolerance
Array
int32
1, 3
RW
SH
UL
412
X
64
Record force ramp
Array
int32
8
RW
SH
UL
Project data, see section 5.4.6
500
1
1
Project zero point
Var
int32
1
RW
SH
NB UL
501
1
2
Lower software end position
Var
int32
1
RW
SH
NB UL
501
2
2
Upper software end position
Var
int32
2
RW
SH
NB UL
507
1
1
Stop ramp
Var
int32
7
RW
SH
UL
510
1
1
Permitted stroke during force
control
Var
int32
1
RW
SH
UL
511
1
1
Lower limit setpoint force
Var
int32
3
RW
SH
NB UL
512
1
1
Upper limit setpoint force
Var
int32
3
RW
SH
NB UL
514
1
1
Permitted speed during force
control
Var
int32
6
RW
SH
UL
521
1
3
Jog mode parameter control
Array
bitarray
0
RW
SH
UL
521
2
3
Direct mode position paraĆ
meter control
Array
bitarray
0
RW
SH
UL
521
3
3
Direct mode force parameter
control
Array
bitarray
0
RW
SH
UL
522
1
2
FHPP: Control/Status bits:
CPOS.HALT support
Struct int32
0
RW
SH IB
UL
522
2
2
FHPP: Control/Status bits:
CCON.BRAKE level
Struct int32
0
RW
SH IB
UL
523
X
8
FHPP: Setpoint/actual values
Struct int32
0
RW
SH
UL
1)
see Tab. 5/15