beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 207

background image

5. Parameter

5−19

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

PNU

1)

Properties

1)

Name (DE)

PNU

UL

NB

IB

SH

RW

Unit

Type

Class

Name (DE)

Max

IND

Record list, see section 5.4.5

400

1

3

Setpoint record number

Struct int32

0

R

400

2

3

Actual record number

Struct int32

0

R

400

3

3

Record status byte

Struct bitarray

0

R

401

X

64

Record control byte 1

Array

bitarray

0

RW

SH

UL

402

X

64

Record control byte 2

Array

bitarray

0

RW

SH

UL

403

X

64

Record param. Control

Array

bitarray

0

RW

SH

UL

404

X

64

Record setpoint value

Array

int32

1, 3

RW

SH

UL

405

X

64

Record preselection value

Array

int32

div.

RW

SH

UL

406

X

64

Record velocity

Array

int32

6

RW

SH

UL

407

X

64

Record acceleration

Array

int32

7

RW

UL

408

X

64

Record deceleration

Array

int32

7

RW

UL

410

X

64

Record workpiece mass

Array

int32

5

RW

UL

411

X

64

Record tolerance

Array

int32

1, 3

RW

SH

UL

412

X

64

Record force ramp

Array

int32

8

RW

SH

UL

Project data, see section 5.4.6

500

1

1

Project zero point

Var

int32

1

RW

SH

NB UL

501

1

2

Lower software end position

Var

int32

1

RW

SH

NB UL

501

2

2

Upper software end position

Var

int32

2

RW

SH

NB UL

507

1

1

Stop ramp

Var

int32

7

RW

SH

UL

510

1

1

Permitted stroke during force
control

Var

int32

1

RW

SH

UL

511

1

1

Lower limit setpoint force

Var

int32

3

RW

SH

NB UL

512

1

1

Upper limit setpoint force

Var

int32

3

RW

SH

NB UL

514

1

1

Permitted speed during force
control

Var

int32

6

RW

SH

UL

521

1

3

Jog mode parameter control

Array

bitarray

0

RW

SH

UL

521

2

3

Direct mode position paraĆ
meter control

Array

bitarray

0

RW

SH

UL

521

3

3

Direct mode force parameter
control

Array

bitarray

0

RW

SH

UL

522

1

2

FHPP: Control/Status bits:
CPOS.HALT support

Struct int32

0

RW

SH IB

UL

522

2

2

FHPP: Control/Status bits:
CCON.BRAKE level

Struct int32

0

RW

SH IB

UL

523

X

8

FHPP: Setpoint/actual values

Struct int32

0

RW

SH

UL

1)

see Tab. 5/15