5. Parameter

5−26

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Build date

PNU

PNU: 103

Index: 1 ... 30

Max index: 30

Class: Array

Data type: char

Values

Default:

Impermissible characters:

Date of creation of the firmware. The date is implemented as a string.
Format DD.MM.YYYY hh:mm:ss"
Example: 03.07.2008 12:40:44

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Software versions

PNU

PNU: 104

Index: 1 ... 2

Max index: 2

Class: Var

Data type: int32

Values

Without unit

Default: 0x0100

Minimum: −

Maximum: −

Software versions of the PlugIn for firmware operation.
Index

Contains

1

Minimal version

2

Recommended version

Format (BCD): 0000HHNN (HH = main version, NN = secondary version)

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Bootloader version

PNU

PNU: 105

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 0x0100

Minimum: −

Maximum: −

Version of the bootloader installed.
In the event of a firmware update the bootloader is not overwritten. Prior to a firmware download,
the system checks whether the firmware to be written is compatible with the bootloader.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.