5. Parameter

5−97

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Commissioning function data reset

PNU

PNU: 1192

Index: 3

Max index: 8

Class: Struct

Data type: int32

Values

Without unit

Default: 0

Minimum: 0

Maximum: 3

This parameter serves to delete axis and identification data.
The axis data must be deleted if a new drive was connected to the CMAX or if the system of measureĆ
ment is to be changed.
Deleting identification data can make sense if modifications were made in the system that lead to a
significantly different positioning behaviour. They need to be deleted if one of the following paraĆ
meters is to be deleted:
Ĉ Cylinder type or cylinder length by more than 5.00 mm
Ĉ Cylinder diameter or piston rod diameter
Ĉ Dual axis" setting
Ĉ Measuring system type or measuring system length of more than 5.00 mm
Ĉ Valve type
Ĉ Supply pressure with a change of more than 1 bar
Ĉ Mounting position with a change of more than 3

°

The parameter can only be written (reading always delivers 0):

= 0: No effect
= 1: reserved
= 2: Delete identification data
= 3: Delete axis data and identification data

When deleting the axis data, the CMAX carries out the following steps:
1. Deactivate controller.
2. Reset axis data to delivery status, delete identification data and adaptation data.
3. Transition to status C00: Waiting for system of measurement
The diagnostic memory is not deleted during axis data reset.

o

The parameter value cannot be changed.

ý

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.