beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 314

background image

A. Notes on commissioning and service

A−6

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Search for axis at

axis interface

Power on

Valve and measuring

system missing

Valve and measuring

system OK

Axis found

Axis not found

Setpoint configuration

not yet available

Setpoint

configuration

available

Setpoint

configuration

available

Waiting for

system of

measurement

units

Controller

ready

PNU 1192:02 = 4

PNU 1192:02 = 0

Fault

PNU 1192:02 = 4

Waiting for

cylinder type

PNU 1192:02 = 1

Waiting for

axis data

PNU 1192:02 = 2

Movement

test

PNU 1192:02 = 3

Controller

ready

PNU 1192:02 = 4

PNU 1192:02 = 0

1

2

3

1

1

Initial start−up executed, CMAX ready
for operation

2

Faults see chapter 4

3

Status when switching on for the first
time (in delivery status or after data
reset) Waiting for initial start−up

Fig. A/1:

Switch−on behaviour