Festo Контроллер позиционирования CPX-CMAX User Manual
Page 221
5. Parameter
5−33
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Time stamp: time of the day
PNU
PNU: 202
Index: 1 ... 100
Max index: 100
Class: Array
Data type: int32
Values
ms
Default: 0
Minimum: −
Maximum: −
Time of the current operating day in milliseconds at the time when the fault occurs.
This time stamp is not a real−time clock. The time is read from the device data PNU 140 when the
fault occurs.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Additional information
PNU
PNU: 203
Index: 1 ... 100
Max index: 100
Class: Array
Data type: bitarray
Values
Default:
0000 0000 0000 0000 0000 0000 0000 0000
Write:
−
The parameter contains detailed information about the fault. This information mainly serves conveniĆ
ent diagnostics using the FCT. The evaluation is complex and therefore not suitable for a PLC proĆ
gram. For description see section 4.3.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Reserved
PNU
PNU: 204
Index: 1
Max index: 5
Class: Struct
Data type: int32
Values
Without unit
Default: 1
Minimum: −
Maximum: −
Reserved. Is not used by the CMAX.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.