beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 171

background image

4. Faults and diagnostics

4−35

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Examples of diagnostic messages

Time stamp

Event

No.

Description

2817d 17h 21.123s

Reset

R01

Reset successfully executed. All the fault messages
were deleted. There is no longer a fault.

2817d 16h 18.123s

Fault

E50

Supply pressure too low (< 1.5 bar)
Last command: Execute record, record number 64

2817d 03h 18.123s

Switch on

P01

Project data available and load (duration of the
initialization: 1289 ms).
Number of switch−on operation since last diagnostic
entry: 219

117d 03h 18.123s

Configu−ration

C05

Static and dyn. identification executed.
Duration: 178 s. Identification was successful.

Tab. 4/10: More examples of diagnostic events

PNU 204: Administration of the diagnostic memory

Index

Description

Default

Min

Max

1, 2

reserved (see section 4.4, PNU 228)

ć

ć

ć

3

Ĉ Write 1: diagnostic memory is deleted.
Ĉ Reading always delivers the value 0
Deleting is usually not required (ring buffer, when the
memory is full, the new entry overwrites the oldest).

0

0

1

4

Number of valid entries. Writing is not permitted.

0

0

100

5

Number of unread entries.
Is set to 0 when index 4 is read. With every new entry
into the diagnostic memory, the value is increased
by 1.

0

0

255

Tab. 4/11: Administration of the diagnostic memory