1 planning aspects when parametrising the cmax, 1 instructions on the available cpx nodes, Planning aspects when parametrising the cmax – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 23: Instructions on the available cpx nodes
1. CPX terminal configuration and FHPP overview
1−3
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
1.1
Planning aspects when parametrising the CMAX
1.1.1
Instructions on the available CPX nodes
Tab. 1/1 shows an overview of the available CPX nodes
(CPX−FEC or CPX bus nodes) that are suitable for operation
with the CMAX (as of August 2009).
CPX node
Required version
1)
Use
For a description see
CPX−CEC
in preparation
On request
ć
CPX−FEC
From Revision 18 (R18)
On request
CPX−FB6 (Interbus)
From Revision 22 (R22)
On request
ć
CPX−FB11 (DeviceNet)
From Revision 20 (R20)
suitable
CPX−FB13 (PROFIBUS−DP)
From Revision 23 (R23)
suitable
CPX−FB14 (CANopen)
From Revision 20 (R20)
On request
ć
CPX−FB23 (CC−Link)
From Revision 19 (R19)
On request
ć
CPX−FB32 (Ethernet/IP)
From Revision 11 (R11)
On request
ć
CPX−FB33 (PROFINET, M12)
From Revision 7 (R7)
On request
ć
CPX−FB34 (PROFINET, RJ45)
From Revision 7 (R7)
On request
ć
CPX−FB38 (EtherCAT)
All
On request
ć
1)
Revisions version (Rev...), see name plate. Older revisions are not suitable for use with the CMAX
and can lead to unpredictable behaviour.
Tab. 1/1: Instructions/special features/references for CPX nodes
General parametrisation instructions are provided in the
description for the used CPX node.